Wired Multi-Mode Gateway
X5 connects Tuya wireless devices through RJ45, Zigbee 3.0 and Bluetooth Mesh. PLC, KNX and RS485 integration requires the corresponding dedicated module.
Compare KNX DALI-2 gateways, the X5 wired multi-mode gateway and KNX integration gateways by verified protocol role, channel capacity, interfaces and commissioning requirements.
Select the gateway family by verified system role before comparing individual models, channel capacity, interfaces and commissioning requirements.
X5 connects Tuya wireless devices through RJ45, Zigbee 3.0 and Bluetooth Mesh. PLC, KNX and RS485 integration requires the corresponding dedicated module.
DDW1.1 and DDW2.1 convert KNX TP commands for DALI-2 lighting control, with one- or two-channel configurations and up to 64 DALI devices per channel.
Two integration configurations support KNX connection to TCP/IP and five RS485 interfaces, or integrate KNX with Tuya Wi-Fi, Zigbee and Bluetooth devices.
Review each gateway by its verified protocol role, channel capacity, interface configuration and project application before moving to the detailed comparison.
X5
A wired gateway for managing Tuya wireless devices through RJ45, Zigbee 3.0 and Bluetooth Mesh. PLC, KNX and RS485 integration uses dedicated modules.
DDW1.1
A single-channel KNX DALI-2 gateway for controlling up to 64 DALI devices, with LAN commissioning and an integrated DALI power supply.
DDW2.1
A dual-channel KNX DALI-2 gateway supporting up to 64 DALI devices per channel and up to 128 devices across both channels.
Multi-System
A DIN-rail integration gateway with KNX TP, TCP/IP connectivity and five RS485 interfaces for connecting KNX installations with other systems.
Wired & Wireless
An integration gateway for connecting KNX installations with Tuya Wi-Fi, Zigbee and Bluetooth devices across wired and wireless control environments.
Compare the five gateway configurations by verified integration role, wired and wireless connectivity, DALI-2 capacity, power requirements and commissioning access.
| Comparison Item | Tuya Gateway Series X5 | KNX DALI Gateway Series DDW1.1 | KNX DALI Gateway Series DDW2.1 | KNX Integration Gateway Series KNX Multi-System | KNX Integration Gateway Series KNX Wired & Wireless |
|---|---|---|---|---|---|
| Integration Role | Wired multi-mode gateway | Single-channel KNX and DALI-2 integration | Dual-channel KNX and DALI-2 integration | KNX multi-system integration | KNX and Tuya wired/wireless integration |
| Core Protocols / Ecosystem | Tuya Zigbee 3.0 · Bluetooth Mesh | KNX TP · DALI-2 | KNX TP · DALI-2 | KNX TP · TCP/IP RS485 interfaces | KNX TP · Tuya Wi-Fi Zigbee · Bluetooth |
| Wired Interfaces | RJ45 Dedicated PLC, KNX and RS485 modules | KNX TP · DALI-2 LAN commissioning | KNX TP · DALI-2 LAN commissioning | TCP/IP · 5 × RS485 KNX TP | KNX TP |
| Wireless Connectivity | Zigbee 3.0 Bluetooth Mesh | — | — | — | Tuya Wi-Fi · Zigbee Bluetooth |
| DALI-2 Channels | — | 1 channel | 2 channels | — | — |
| DALI Device Capacity | — | Up to 64 devices | Up to 64 devices per channel Up to 128 devices total | — | — |
| Power Supply | 110–240 VAC 50/60 Hz | 230 VAC auxiliary KNX 30 VDC | 230 VAC auxiliary KNX 30 VDC | KNX bus 21–30 VDC | KNX bus 21–30 VDC |
| Dimensions | 185 × 135 × 32 mm | 72 × 94.5 × 64.5 mm | 72 × 94.5 × 64.5 mm | 108 × 90 × 64 mm | 72 × 90 × 64 mm |
| Operating Temperature | −20°C to +70°C | −5°C to +45°C | −5°C to +45°C | −5°C to +45°C | −5°C to +45°C |
| Configuration / Access | Tuya device management | LAN commissioning | LAN commissioning | iPad · iPhone · Android Home Assistant integration | Tuya App OTA update support |
RS485 and TCP/IP are shown only as verified interfaces. This comparison does not claim standard Modbus, BACnet, Matter or HomeKit compatibility.
Send us your required protocols, DALI channel count, device quantity, RS485 interfaces and commissioning method for product selection support.
Start with the systems that must communicate, then compare the verified protocols, interfaces, channel capacity, device quantity and commissioning method.
Use X5 when a project needs a wired gateway for Tuya wireless devices connected through RJ45, Zigbee 3.0 and Bluetooth Mesh.
PLC, KNX and RS485 connectivity uses the corresponding dedicated modules and should not be presented as standard built-in connectivity.
Use the KNX DALI-2 gateway family when KNX commands must control DALI lighting devices through one or two independent DALI channels.
Select DDW1.1 or DDW2.1 according to the required channel count, device quantity and commissioning requirements.
Use this integration role when a KNX installation requires TCP/IP connectivity and multiple RS485 interfaces for connection with other systems.
RS485 and TCP/IP identify verified physical or network interfaces. They do not by themselves confirm Modbus, BACnet or another standard protocol.
Use this gateway role when a KNX installation must integrate with Tuya Wi-Fi, Zigbee and Bluetooth devices across wired and wireless control environments.
Confirm the required platform, device quantity, automation scope and local or remote control method before final product selection.
A reliable gateway selection begins with the systems that must communicate and the verified technical limits of each connection.
Position each gateway according to the systems that must communicate, the verified interfaces available and the required wired or wireless project architecture.
DDW1.1 or DDW2.1 connects KNX TP control with one or two DALI-2 lighting channels, supporting up to 64 devices per channel.
X5 manages Tuya wireless devices through Zigbee 3.0 and Bluetooth Mesh with RJ45 network access.

The KNX multi-system gateway provides TCP/IP connectivity and five RS485 interfaces for linking a KNX installation with other systems.
The wired and wireless integration gateway connects KNX with Tuya Wi-Fi, Zigbee and Bluetooth devices within one project.
Gateway selection should follow the building systems, device quantities, lighting channels and network interfaces required by each project.

Coordinate KNX lighting and Tuya wireless devices across villas, apartments and premium residential projects.

Support connected lighting, room-control equipment and building integration across hospitality projects.

Connect lighting, network and verified field interfaces across offices and commercial building projects.
Request the technical documents required for product evaluation, installation, system connection and gateway commissioning.
Request electrical data, dimensions, channel capacity, interfaces and product-specific technical parameters.
Request mounting, power connection, installation, commissioning and product-dimension information.
Request verified KNX, DALI-2, power, LAN and RS485 connection references for the selected gateway.
Request the applicable commissioning database, configuration tool or software package for the selected gateway.
Review common questions about KNX DALI-2 gateways, Tuya wireless integration, TCP/IP and RS485 interfaces, device capacity and technical documentation.
DDW1.1 is a single-channel KNX DALI-2 gateway supporting up to 64 DALI devices.
DDW2.1 provides two DALI-2 channels, supporting up to 64 devices per channel and up to 128 devices in total. Both models support KNX TP, LAN commissioning and an integrated DALI power supply.
X5 provides RJ45 network access, Zigbee 3.0 and Bluetooth Mesh connectivity.
KNX, PLC and RS485 connections are available through optional dedicated modules.
No. RS485 identifies the physical communication interface and does not by itself confirm Modbus or another application protocol.
The required RS485 protocol must be checked against the formal documentation for the selected gateway.
The KNX Wired & Wireless Integration Gateway connects KNX TP with Tuya Wi-Fi, Zigbee and Bluetooth devices.
It supports up to 200 KNX channels, more than 400 wireless devices and up to 1000 control devices in the app environment.
The KNX Multi-System Integration Gateway provides KNX TP, TCP/IP and five RS485 interfaces.
It is designed for KNX projects that require network integration and multiple RS485 connections within one system architecture.
No. Matter, HomeKit, BACnet and Modbus are not standard capabilities of the gateway models included on this page.
TCP/IP, RJ45 and RS485 describe communication interfaces and do not add these protocols.
Start by identifying the systems that must communicate, then confirm the required protocol or interface, DALI channel count, device quantity, wired or wireless architecture, power supply and commissioning method.
The gateway should be selected from these project requirements rather than from the product name alone.
Available document requests may include product datasheets, installation manuals, dimension drawings, wiring diagrams and the applicable ETS, DCA or configuration files.
The exact document type depends on the selected gateway and its commissioning requirements.
Share the systems you need to connect, the required interfaces, channel quantities, device capacity and commissioning method. Our team will help you select the appropriate gateway configuration and technical resources.
Please enter the authorization code provided by DERVIRGA to download this file.
Fill out the form below, and we will be in touch shortly.